Product Details
Product Center
Male Sexual Function Biofeedback Device
Penile Rigidity Monitoring: --Product Features-- ① Nighttime Erection Monitoring: By wearing a disposable pressure band sensor placed at the base of the penis, this feature continuously records changes in the number, hardness, and duration of nocturnal erections over an 8-hour or longer period during sleep, helping clinicians determine the nature of a patient’s erectile dysfunction. ② On-Site Erection Monitoring: After administering medication or using VR video stimulation, the same disposable pressure band sensor is worn at the base of the penis to track real-time changes in penile erection data within 30 minutes post-stimulation. --Product Highlights-- ① Provides quantitative measurement of axial penile rigidity. ② Enables continuous monitoring for more than 8 hours, offering an objective and accurate assessment of a patient’s erectile capability. ③ Equipped with single-use sensors to prevent cross-contamination. ④ Includes an intelligent analysis system that automatically generates detailed test reports. Clinical Application: The smart data analysis tool aids in differentiating between psychogenic ED (caused by psychological factors) and organic ED (resulting from physical conditions). Doppler Ultrasound Examination Function: --Product Features-- This function uses an ultrasound probe to emit sound waves into the body’s blood vessels. The probe then captures the returning echo signals, allowing for real-time monitoring of the cavernosal arteries in the penis. Simultaneously, it records both systolic and diastolic blood pressures. A computerized system automatically calculates the penile blood flow index, while also measuring peak systolic velocity, mean blood flow velocity, and other relevant parameters. Penile blood flow testing is currently one of the most valuable methods for diagnosing vascular erectile dysfunction (ED). Commonly used parameters to assess penile vascular function include cavernosal artery diameter, peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistance index (RI). Typically, after injecting vasodilatory drugs, a cavernosal artery diameter greater than 0.7 mm—or an increase of more than 75%—along with PSV ≥ 30 cm/s, EDV ≤ 5 cm/s, and RI > 0.8 indicates normal function. Conversely, PSV < 30 cm/s suggests inadequate arterial blood supply, while EDV > 5 cm/s and RI < 0.8 may indicate incomplete venous occlusion. --Product Highlights-- ① Features automatic identification of penile blood flow velocity and other key parameters. ② Allows independent analysis and printing of comprehensive reports. ③ Uses plug-and-play detection probes for easy disinfection and maintenance. Clinical Application: Ideal for assessing vascular causes of erectile dysfunction. Neurophysiological Testing: --Product Features-- Neurophysiological testing employs electrophysiological instruments and microelectrodes to elicit evoked potentials from specific sensory receptors in response to stimuli such as vibrational input. This technique involves electrically stimulating the dorsal nerve of the penis and the glans area, enabling the measurement of dorsal nerve somatosensory evoked potentials (DNSEP) and glans somatosensory evoked potentials (GPSEP) on the scalp. These measurements help evaluate changes along the entire neural pathway—from the penile dorsal nerves to the central nervous system. --Product Highlights-- ① Supports simultaneous testing of both the penile dorsal nerve and the glans region. ② Offers a non-invasive, safe, and highly effective testing approach. ③ Features intelligent data analysis capabilities and automatically generates standardized report templates. Clinical Application: Used to assess abnormalities in both somatic and autonomic nerve functions. Sensitivity Threshold Testing: --Product Features-- Utilizing advanced ultramicro-vibration wave technology, this test quantitatively evaluates the sensitivity levels of sensory nerves in various penile areas by measuring their respective bio-vibration thresholds. It assesses the functional integrity of sex-related nerves and helps evaluate how effectively the central nervous system regulates excitatory responses. Early diagnosis of neurologically induced premature ejaculation can be achieved through this bio-vibration sensitivity threshold assessment. --Product Highlights-- ① Can test up to six distinct penile areas per session for sensitivity thresholds. ② Employs a fully automated computer-controlled analysis software system. ③ Uses single-use consumables to eliminate the risk of cross-contamination.
Category:
Male Sexual Function Biofeedback Device
Contact us
Product Description
Penile Rigidity Test:
--Product Features--
① Nighttime Erection Monitoring: By wearing a disposable pressure-bandage sensor placed at the base of the penis, this device can continuously record changes—such as the number, rigidity, and duration—of nocturnal erections over an 8-hour or longer period during sleep, helping clinicians determine the nature of a patient’s erectile dysfunction.
② On-site Erection Monitoring Function: During the test, after administering medication or using VR video stimulation, a disposable pressure-band sensor is worn at the base of the penis to continuously record the changes in erectile response over a 30-minute period following drug stimulation.
--Product Features--
① Quantitative measurement of penile axial rigidity
② Can perform continuous monitoring for more than 8 hours, objectively evaluating and accurately reflecting the patient’s penile erectile function.
③ Equipped with single-use sensors for monitoring, helping to prevent cross-infection.
④ Intelligent analysis system automatically generates inspection reports.
Clinical application: Intelligent data analysis for the differential diagnosis of psychogenic and organic ED.
Doppler ultrasound examination features:
--Product Features--
By emitting ultrasound waves into the human body's blood vessels via an ultrasonic probe, the probe then captures the returning echo signals. This allows for real-time monitoring of the penile cavernosal artery, while simultaneously recording both systolic and diastolic blood pressure. The system automatically calculates the penile blood flow index using a computer, also providing data on peak blood flow velocity and mean blood flow velocity.
Penile blood flow testing is currently one of the most valuable methods used to diagnose vascular erectile dysfunction (ED). Common parameters used to assess penile intravascular function include cavernosal artery diameter, peak systolic velocity (PSV), end-diastolic flow velocity (EDV), and resistance index (RI).
It is generally accepted that after administering vasoactive drugs, a penile cavernosal artery inner diameter greater than 0.7 mm—or an increase of more than 75%—along with a peak systolic velocity (PSV) of ≥30 cm/s, an end-diastolic velocity (EDV) ≤5 cm/s, and a resistance index (RI) >0.8, indicates normal function. PSV <30 cm/s suggests inadequate arterial blood supply, while EDV >5 cm/s and RI <0.8 may indicate incomplete venous occlusion in the penis.
--Product Features--
① Features automatic identification of parameters such as penile blood flow velocity
② Can independently analyze and print reports
③ Plug-in detection probe for convenient disinfection and easy maintenance afterward
Clinical application: Suitable for the detection of vascular ED.
Neuroelectrophysiological Testing:
--Product Features--
Neurophysiological electrophysiological testing uses electrophysiological instruments and microelectrodes to evoke specific sensory evoked potentials in targeted sensory pathways by stimulating receptors—such as vibration—in a controlled manner. For instance, electrical stimulation of the dorsal penile nerve and the glans penis can generate dorsally evoked somatosensory potentials (DNSEP) and glans-evoked somatosensory potentials (GPSEP), which can then be recorded from the scalp. These measurements provide valuable insights into changes along the entire central pathway through which sensory signals from the dorsal penile nerve are transmitted to the brain.
--Product Features--
① Can simultaneously be used for detecting the dorsal penile nerve and the glans penis area.
② Non-invasive testing solution—safe and effective
③ Intelligent data analysis, automatically generating report templates
Clinical application: Used to assess abnormalities in patients' somatic and autonomic nervous functions.
Sensitive threshold detection:
--Product Features--
By employing ultra-microbiotic vibration wave technology, this method quantitatively assesses the sensitivity of sensory nerves in areas such as the penis by measuring the biological vibration thresholds across different penile regions. It also evaluates the conduction function of sex-related nerves and the central nervous system's ability to modulate arousal. Utilizing bio-vibration sensation threshold measurements allows for earlier diagnosis of premature ejaculation caused by neurological factors.
--Product Features--
① Up to 6 body areas can be tested for sensitivity thresholds in a single session.
② Computerized Fully Automatic Control and Analysis System Software
③ Use single-use consumables to prevent cross-infection.
Previous page
Related Products